Disassembling
| Pull the Cap Lock towards the Mouthpiece. | |
| Pull the Cooling Unit Cap off the Vaporizer. | |
Pull the Mouthpiece out of the Cooling Unit Cap while slightly tilting it back and forth. Pull off the Mouthpiece Seal Ring. | |
When cleaning the Cooling Unit Cap in isopropyl alcohol, remove the Cap Lock by pulling it up on one side. First press the Cap Lock on one side and pull it up on the opposite side. | |
| Then slide the Cap Lock on the raised side towards the opposite side. | |
| Unscrew the Cooling Unit base from the Vaporizer by turning it 90° counterclockwise. | |
Lever out the large Base Seal Ring with Filling Chamber Tool at the recess in the groove. Remove the small Base Seal Ring. | |
| Push out the Screen from the Cooling Unit Base with the help of the Filling Chamber Tool. |
Assembling
To assemble follow the instruction in reverse order.
- Insert the small Base Seal Ring completely into the Cooling Unit Cap.
► The small Base Seal Ring is no longer visible. - When assembling, make sure that Seal Rings are properly seated.
- Insert Screen in the groove provided for this purpose.