Temperature Adjustment
- The VOLCANO CLASSIC features an adjustable temperature range from 130°C to 230°C (266°F to 446°F).
- The analog temperature dial on the front of the device lets you easily select your desired heat level.
Heat Up
- To switch on the heater, push the rocker switch labeled “HEAT“.
- The rocker switch will light up, signaling that the heater is in operation. At the same time, the yellow control lamp will be signaling that the device is heating up.► This heating process of the heat exchanger can take up to 5 minutes depending upon the chosen temperature.
- Once the set temperature is reached, the control light will turn off, signaling that the heat exchanger has finished warming up and the device is ready for use.
💡 If the temperature in the heat exchanger drops, the heat exchanger will automatically heat up, which is signaled by the yellow control lamp lighting up again. 💡The vaporization temperature may fluctuate about ± 5°C (± 9°F) related to the indicated values because of the heating and cool off process of the heat exchanger. |
Vapor Cooling System and Inhalation Temperature
To ensure a smooth and pleasant inhalation experience, the VOLCANO CLASSIC can be used with the EASY VALVE or the SOLID VALVE Balloon System, which provides a large surface area for vapor to cool effectively before inhalation.
During use, several factors can influence the final inhalation temperature:
- The fill level of the chamber
- The selected vaporization temperature
- The strength and duration of your draw